Skip to main content

An interdisciplinary debate on project perspectives

Table 2 Basic information for examples of mid-rise buildings, based on (Alnusairat 2018; Alsheghri et al. 2015; Bai et al. 2015; Abass et al. 2016)

From: Natural ventilation as a passive cooling strategy for multi-story buildings: analytic vertical skycourt formations

Building name

Masdar institute

Business promotion center

Dongguan’s Eco-Park Office Buildings

The Courtyard House

Schematic

View full size image

View full size image

View full size image

View full size image

Location

Abu Dhabi, United Arab Emirates

Duisburg, Germany

Dongguan, China

Rajasthan, India

Climate

Hot and dry

Warm and temperate

Humid Subtropical

Hot and dry

Completion Year

2010

2004

2013

2012

Use

Laboratories and Library

Offices

Offices

Residential

Height (m)

21 m

30 m

23.9 m

10 m

No. of Floors

3

4

6

2

Gross Area (m2)

63000 m2

4000 m2

37664 m2

3000 m2

Ventilation Type

Natural ventilation

Natural ventilation

Natural ventilation

Natural ventilation

Natural Ventilation Type

Cross

Stack

Stack

Stack

Night-time Ventilation

√

√

√

-

Annual Usage of Natural Ventilation

100%

100%

100%

95%

Annual Energy Saving

100%

57%

63%

79%

Annual Energy Consumption

–

13 kWh/m2

125 kWh/m2

–